Orchestral concert hall with rear choir stalls
Capacity:
1260 in open orchestral platform configuration
1078 in Black Box Configuration.
Stage:
Orchestral Wood platform with curved downstage edge.
Overhead wooden acoustic canopy
12m wide upstage, 20m wide downstage, 12m deep, 1m high.
Clearance to canopy:10m
Clearance to rigging beams above canopy 15m
Mix Position:
Rear of bleachers under balcony in seat rows V,W and X (42 seats used from room seating capacity ie black box config with mix is1036) Mix size is 7m wide 2 m deep.
Rigging:
Rigging only from five beams running upstage, downstage 2m apart from centre.
Maximum weight per beam 2000kg .
Lighting System:
Front truss, 15m: 6x6 way bar par 64 cp 61
Back truss, 11.5m 10x6way par 64 cp60.
Drapes truss, upstage 11m and side stage left and right 2x 9m
Floor, 10x floor cans par 64 cp 61
FOH, 10X 2.5K profiles
Follow Spots. 2x 2.5k Lycian 1290 XLT (house operators only)
10 x Source 4 Zoom
4 x 4 lites
Desk, STRAND 520I 2.5i
Sound System:
14 x Meyer Sound MS M2D Line Array full range loudspeakers
( 7 a-side flown in fixed positions on 1000kg points CM motors stage right & stage left)
4 x Meyer Sound M2D /SUB Line Array Subwoofers flying
(1 a-side flown )
6 x Meyer Sound MS-UPM-1P Front Fill full range loudspeakers
(3 a-side splayed left and right stereo front fills)
2 x Meyer Sound MS-UPM-1P under balcony full range loudspeakers
(under balcony delay fills house right and house left)
3 x Meyer MS-UPA-1P full range loudspeakers
(flown on fixed points under acoustic canopy as rear choir stalls fills)
6 x Meyer MS UM-1P full range stage monitor cabs
(4 monitor sends from FOH console)
FOH equipment:
Midas Legend 3000,44/4 dual PSU , mixing console
1 x XTA DP224 Speaker Management System
1 x XTA DP226 Speaker Management System
2 x DN360 1/3 Octave Graphic Equalizer ( FOH flying L & R )
1 x DN300 1/3 Octave Graphic Equalizer (Rear Fills)
2 x DN332 Graphic Equalizer ( Under Balcony and front fills )
2 x DN332 Graphic Equalizer ( 4 x monitor Mixes )
Insert Racks:
3 x Klark Tecknic DN514 Quad Gates
6 x Klark Tecnic DN500 Compressor /Limiters
FX Rack:
1x Yamaha SPX 990
2 x Yamaha REV500
1 x TC D2
Microphones:
6 X AKG 451
4 X BETA SM 58
6 X SM 58
6 X SM 57
3 X AGK 414
2 AKG 3000
2 AKG 568EB
1 X D112
1 X BETA 52
12 X LBB100 DI ACTIVE
2 X SHURE U258 TRANSMITTER MIKES
2 X SHURE CLIP TRANSMITTER MIKES
1 X SHURE U4D RADIO RECIEVER UNIT
24 X KM MIKE STANDS WITH BOOM ARMS
Power:
Visiting Lights Power 200A / 3 Phase / 220/315V
Visiting Sound Power 100A / Single Phase / 240V
OB1 outside broadcast power 32A or 63A or 125A / 3 Phase /220/ 315 V
switcheable generator incoming power facility
Bus Power 16A / 32A / 63A 220V single phase available
Rigging power 32A / 220/315V 3 Phase on catwalk, stage end.
Intercom:
Canford A/B Dual Channel , FOH x 2 , Stage Left , Stage Right , 2 x Follow Spots, Show Relay to Dressing rooms , Green Room and Hallway.
Load In:
Two truck dock at stage height , through double doors. 5m push to stage
View the seating plan of the upper floor or the lower floor of Mahony Hall. |